Proven technology, proven design –
decide for the best solution

PANDA WV 1200 - 2400 A

  • Efficient:
    minimized operating costs
  • Reliable:
    robust construction made of GGG40 material, standard mechanical shaft seals, reliable under varying operating conditions, solid lobe design for high particle tolerance, barrier gas connection
  • High Performance:
    high pumping speed due to excellent volumetric efficiency, integrated bypass valve
  • Easy Servicing:
    minimal maintenance


Due to their high pumping speed and ultimate pressure, Panda WV vacuum boosters increase the performance of vacuum pumps. Available in various sizes, Panda WV vacuum boosters can be designed to perfectly suit all rough and medium vacuum applications in which the performance of the backing pump needs to be significantly increased or optimally adapted to the process. The Panda WV 1200 – 2400 A feature our latest improved design in GGG40 and are optimized for use in a wide range of applications including ATEX and chemical processes.

Panda WV are the perfect vacuum boosters for all types of backing pumps. When using a combination of backing pump and vacuum booster, the pumping speed and ultimate pressure of a vacuum system can be increased by up to a factor of 10. As a result, these combinations can generate a suction performance which would otherwise only be possible with a large number of backing pumps.

Thanks to the integrated bypass valve, Panda WV vacuum boosters achieve a high pumping speed even in rough vacuum applications. It reliably protects against overloading and allows the Panda WV to be switched on together with the backing pump even at atmospheric pressure without further action. A process-related, sudden pressure increase due to a higher gas flow can be easily handled by the bypass valve in continuous operation.

Panda WV vacuum boosters can be flanged directly onto the backing pump or at any other position on the system thanks to our large and specially designed portfolio of adapters.


Panda – the economical performance optimizer.

Panda – the economical performance optimizer.

Want to know more?
Contact us directly (Busch Australia):
1800 639 087 Get in contact

Technical Specifications

Technical specifications
Within the housing of Panda WV vacuum boosters, two lobes rotate synchronously. Due to the special profile of the lobes and their precise manufacturing, they do not come in contact with each other or the housing. Thus, no lubricants or operating fluids are required in the process chamber. The two lobes are driven by a pair of gear wheels separated from the process chamber. The integrated bypass valve, which comes as standard, enables an operation around atmospheric pressure or at rough vacuum without the need for a special controller. Busch vacuum boosters are driven by a directly coupled electric motor of efficiency class IE3, for electrical network worldwide.

Dimensional Drawing
Pumping speed

Air at 20 °C. Tolerance: ± 10%

50 Hz 60 Hz
Pumping speed
Technical data PANDA WV 1200 A PANDA WV 1800 A PANDA WV 2400 A
Nominal pumping speed 1050 m³/h 1600 m³/h 2120 m³/h
Pumping speed 950 m³/h* 1443** m³/h 1920 m³/h**
Max. pressure differential 53 hPa (mbar) 53 hPa (mbar) 53 (70) hPa (mbar)***
Nominal motor rating 3.5 kW 4.3 kW 6.0 kW
Nominal motor speed 3000 min-1 3000 min-1 3000 min-1
Weight approx. 290 kg 300 kg 520 kg
Dimensions (L x W x H) 1094 x 470 x 353 mm 1114 x 470 x 398 mm 1286 x 568 x 503 mm
Gas inlet / outlet (vertical) DN 160 ISO / DN 100 ISO DN 160 ISO / DN 100 ISO DN 160 ISO / DN 160 ISO
Gas inlet / outlet (lateral) DN 160 ISO / DN 100 ISO DN 160 ISO / DN 100 ISO DN 160 ISO / DN 160 ISO
* with COBRA NC 0400 as backing pump ** with COBRA NC 0630 as backing pump *** option available after process evaluation

Technical Specifications

Technical specifications
Within the housing of Panda WV vacuum boosters, two lobes rotate synchronously. Due to the special profile of the lobes and their precise manufacturing, they do not come in contact with each other or the housing. Thus, no lubricants or operating fluids are required in the process chamber. The two lobes are driven by a pair of gear wheels separated from the process chamber. The integrated bypass valve, which comes as standard, enables an operation around atmospheric pressure or at rough vacuum without the need for a special controller. Busch vacuum boosters are driven by a directly coupled electric motor of efficiency class IE3, for electrical network worldwide.

Dimensional Drawing
Pumping speed

Air at 20 °C. Tolerance: ± 10%

50 Hz
60 Hz
Pumping speed
Technical data PANDA WV 1200 A PANDA WV 1800 A PANDA WV 2400 A
Nominal pumping speed 1050 m³/h 1600 m³/h 2120 m³/h
Pumping speed 950 m³/h* 1443** m³/h 1920 m³/h**
Max. pressure differential 53 hPa (mbar) 53 hPa (mbar) 53 (70) hPa (mbar)***
Nominal motor rating 3.5 kW 4.3 kW 6.0 kW
Nominal motor speed 3000 min-1 3000 min-1 3000 min-1
Weight approx. 290 kg 300 kg 520 kg
Dimensions (L x W x H) 1094 x 470 x 353 mm 1114 x 470 x 398 mm 1286 x 568 x 503 mm
Gas inlet / outlet (vertical) DN 160 ISO / DN 100 ISO DN 160 ISO / DN 100 ISO DN 160 ISO / DN 160 ISO
Gas inlet / outlet (lateral) DN 160 ISO / DN 100 ISO DN 160 ISO / DN 100 ISO DN 160 ISO / DN 160 ISO
* with COBRA NC 0400 as backing pump ** with COBRA NC 0630 as backing pump *** option available after process evaluation