Proven technology, proven design –
decide for the best solution

MINK MP 0400 - 0960 AV

Mink MP vacuum modules are designed for operations in which high suction volumes, dry compression and high reliability are required. They consist of two or three proven Mink claw vacuum pumps connected in parallel. The pumps operate in a non-contact manner, so that no operating fluid such as oil or water is required for the compression process.

Modular design
Due to the modular design, Mink MP vacuum modules can be adapted to customer needs.

Low maintenance
Due to the non-contact compression, there is no friction in the compression chamber and no wear caused by the pump operation.

Economical
Due to the high degree of efficiency compared with other vacuum principles, considerable energy saving is possible. The reduction of maintenance work minimizes downtime and costs for wear parts and operating fluid. The operation of frequency-controlled motors is possible, meaning that further energy savings can be realized.


Mink – save up to 60% on your operating costs for vacuum generation.

Mink – save up to 60% on your operating costs for vacuum generation.

Want to know more?
Contact us directly (Busch Turkey):
+90 (0)216 3100573 Get in contact

Technical Specifications

Technical Specifications
Two or three Mink claw vacuum pumps are connected in parallel. In each of these pumps, two claws rotate in opposite directions in a housing. Due to the special geometric form of the claws, air that is sucked in is compressed inside the vacuum pumps. Air is sucked in via the inlet flange, compressed in the compression chamber and expelled again on the pressure side. The non-return valve is integrated into the suction pipe as standard. This prevents ventilation of the recipient through the pumps when turning the pumps off. The Mink claw vacuum pumps are powered by standard motors. A synchronization gearbox ensures exact synchronization of both claws. Due to the parallel connection of the vacuum pumps, the pumping speeds of the individual machines accumulate to a total suction volume. The air filters in front of each of the Mink vacuum pumps are fitted as standard. Individual pump silencing measures are also possible.

Dimensional Drawing MINK MP 0400 - 0960 AV
MINK MP 0400 - 0960 AV
Pumping speed

Air at 20 °C. Tolerance: ± 10% 

50 Hz 60 Hz
Pumping speed
Technical data MINK MP 0400 AV MINK MP 0500 AV MINK MP 0600 AV MINK MP 0640 AV MINK MP 0750 AV MINK MP 0960 AV
Nominal pumping speed 400 m³/h 500 m³/h 600 m³/h 600 m³/h 750 m³/h 900 m³/h
Ultimate pressure 100 hPa (mbar) 100 min-1 100 hPa (mbar) 150 hPa (mbar) 100 hPa (mbar) 150 hPa (mbar)
Nominal motor rating 2x 4.0 kW 2x 4.5 hPa (mbar) 3x 4.0 kW 2x 5.5 kW 3x 4.5 kW 3x 5.5 kW
Nominal motor speed 3000 min-1 3000 kW 3000 min-1 3000 min-1 3000 min-1 3000 min-1
Noise level (ISO 2151) 78 dB(A) 78 dB(A) 80 dB(A) 80 dB(A) 80 dB(A) 82 dB(A)
Weight approx. 660 kg 680 kg 940 kg 1025 kg 970 kg 1075 kg
Dimensions (L x W x H) 1588 x 860 x 2582 mm 1588 x 860 x 2582 mm 1588 x 860 x 2582 mm 1588 x 860 x 2582 mm 1588 x 860 x 2582 mm 1588 x 860 x 2582 mm
Gas inlet / outlet DN 100 KF / DN 100 KF DN 100 KF / DN 100 KF DN 100 KF / DN 100 KF DN 100 KF / DN 100 KF DN 100 KF / DN 100 KF DN 100 KF / DN 100 KF

Technical Specifications

Technical Specifications
Two or three Mink claw vacuum pumps are connected in parallel. In each of these pumps, two claws rotate in opposite directions in a housing. Due to the special geometric form of the claws, air that is sucked in is compressed inside the vacuum pumps. Air is sucked in via the inlet flange, compressed in the compression chamber and expelled again on the pressure side. The non-return valve is integrated into the suction pipe as standard. This prevents ventilation of the recipient through the pumps when turning the pumps off. The Mink claw vacuum pumps are powered by standard motors. A synchronization gearbox ensures exact synchronization of both claws. Due to the parallel connection of the vacuum pumps, the pumping speeds of the individual machines accumulate to a total suction volume. The air filters in front of each of the Mink vacuum pumps are fitted as standard. Individual pump silencing measures are also possible.

Dimensional Drawing
MINK MP 0400 - 0960 AV
MINK MP 0400 - 0960 AV
Pumping speed

Air at 20 °C. Tolerance: ± 10% 

50 Hz
60 Hz
Pumping speed
Technical data MINK MP 0400 AV MINK MP 0500 AV MINK MP 0600 AV
Nominal pumping speed 400 m³/h 500 m³/h 600 m³/h
Ultimate pressure 100 hPa (mbar) 100 min-1 100 hPa (mbar)
Nominal motor rating 2x 4.0 kW 2x 4.5 hPa (mbar) 3x 4.0 kW
Nominal motor speed 3000 min-1 3000 kW 3000 min-1
Noise level (ISO 2151) 78 dB(A) 78 dB(A) 80 dB(A)
Weight approx. 660 kg 680 kg 940 kg
Dimensions (L x W x H) 1588 x 860 x 2582 mm 1588 x 860 x 2582 mm 1588 x 860 x 2582 mm
Gas inlet / outlet DN 100 KF / DN 100 KF DN 100 KF / DN 100 KF DN 100 KF / DN 100 KF
Technical data MINK MP 0640 AV MINK MP 0750 AV MINK MP 0960 AV
Nominal pumping speed 600 m³/h 750 m³/h 900 m³/h
Ultimate pressure 150 hPa (mbar) 100 hPa (mbar) 150 hPa (mbar)
Nominal motor rating 2x 5.5 kW 3x 4.5 kW 3x 5.5 kW
Nominal motor speed 3000 min-1 3000 min-1 3000 min-1
Noise level (ISO 2151) 80 dB(A) 80 dB(A) 82 dB(A)
Weight approx. 1025 kg 970 kg 1075 kg
Dimensions (L x W x H) 1588 x 860 x 2582 mm 1588 x 860 x 2582 mm 1588 x 860 x 2582 mm
Gas inlet / outlet DN 100 KF / DN 100 KF DN 100 KF / DN 100 KF DN 100 KF / DN 100 KF